AHP/AHPH Series

Product Type

Heat Exchanger

Solution

Compressed Air Cooling

Application

Industrial Applications

Technology

Air Cooled, Brazed Aluminum

Air-Cooled Compressed Air Aftercooler — Bar & Plate Aluminum, Vertical or Horizontal Airflow

The Thermal Transfer Products AHP/AHPH Series is a high-performance air-cooled aftercooler purpose-built for cooling compressed air. Its rugged, heavy-duty bar-and-plate aluminum core is optimized for high airflow, low pressure drop, and maximum heat transfer, and its energy-efficient design also makes it well suited to heat-recovery applications. Both models carry a durable black powder-coat finish and are backed by downloadable 3D CAD models, technical documentation, and application engineering support to simplify OEM integration.

The AHP is the vertical-airflow version, discharging hot air up and away from operators, with detachable legs (shipped unattached) for floor or suspension mounting. It includes nine models with flow capacities from 125 to 4,800 SCFM (3.5–135.9 SCMM), sized for compressors from 60 to 700 HP (45–520 kW).

The AHPH is the horizontal-airflow version with fixed mounting feet, for installations where side-discharge suits the layout better. It includes six models with flow capacities from 30 to 2,800 SCFM (1–80 SCMM), sized for compressors from 60 to 400 HP (45–298 kW). Fan options include electric TEFC and air-motor drives. The AHP/AHPH Series is the current replacement for the obsolete UPA and AA aftercooler lines — crossover information is in the AHP/AHPH brochure. TTP’s XSelector® sizing program helps select the right model for your airflow and compressor.

UPA and AA are obsolete.

For the crossover information, please refer to page 3 in the AHP/AHPH series brochure.

Consult catalog for additional sizes and technical information.

Product Features

  • Full line of sizes and features
  • Brazed bar and plate aluminum core
  • Energy efficient
  • High performance
  • High flows 50-3500 CFM
  • Vertical (AHP) or horizontal (AHPH) air flow
  • High technology compact design
  • Rugged heavy duty construction
  • Excellent for heat recovery
  • Detachable legs on AHP (shipped unattached). Fixed mounting Feet on some AHPH models
  • CRN Available
Ratings
Maximum Operating Pressure 250 PSI
Maximum Operating Temperature 350°F
Flow Rate 50–3500 CFM
*CRN Rating 235 PSI at 250°F (121°C)
Materials
Cabinet Steel with baked enamel finish
Core Brazed aluminum bar and plate
Fan Aluminum hub, polypropylene blades
Shroud Painted steel
Motor TEFC
Fan Guard Steel with baked enamel finish
Product Options
Air Motor
Detachable legs on AHP (shipped unattached). Fixed mounting Feet on some AHPH models
  • All catalog product is available with short lead-times, ensuring fast delivery and dependable supply
  • Expert application engineers are available to select and size the right product for your application
  • Custom designs are available
  • Replacement parts and maintenance support keep your systems running with minimal downtime
  • Procurement advantage: designed to meet global standards while reducing overall total cost of ownership

Can I download CAD models and technical documentation to help integrate Thermal Transfer Products’ coolers into my system?

Yes. Thermal Transfer Products provides CAD models in multiple formats and full technical documentation, including datasheets and service manuals, are available through our configurator and resources hub.

Why choose Thermal Transfer Products for lead time, quality, and cost?

Thermal Transfer Products are known for our superior quality with shortest lead times in the industry, all making for a good value for heat exchanger packages.

How quickly can Thermal Transfer Products deliver heat exchangers?

TTP offers short lead times across our catalog products. With CAD configurator tools and expert engineering support, OEM engineers can move from design to delivery quickly, without compromising on performance or quality.

Documents

Frequently Asked Questions

It’s a high-performance air-cooled compressed air aftercooler from Thermal Transfer Products, built on a bar-and-plate aluminum core and designed specifically for cooling the hot air discharged by air compressors.

Airflow direction and mounting. The AHP uses vertical airflow (hot air up and away from operators) with detachable legs for floor or suspension mounting. The AHPH uses horizontal airflow with fixed mounting feet. Choose based on how you need to direct exhaust air and how the unit mounts in your space.

The AHP has nine models, 125–4,800 SCFM (3.5–135.9 SCMM), for compressors from 60–700 HP (45–520 kW). The AHPH has six models, 30–2,800 SCFM (1–80 SCMM), for compressors from 60–400 HP (45–298 kW).

It needs no cooling-water supply — useful where water isn’t available or you want to avoid water and sewer costs. For water-cooled aftercooling, see TTP’s AB Series.

Electric TEFC motors and air-motor drives, depending on the model and application.

Yes. The UPA and AA lines are obsolete, and the AHP/AHPH is the current replacement — crossover/model-conversion information is on page 3 of the AHP/AHPH brochure.

Configure the AHP/AHPH Series

3D Configurator

Our 3D Product Configurator will allow you to build up the cooler with specific options that are required for your application, view what you have created in 3D, then download the model directly into your format to complete your modeling project.

Talk to an engineer at TTP.

Finding the right thermal management solution shouldn’t be a guessing game. Whether you need a quick price quote, technical specs, or a fully custom engine cooling system designed from the ground up, our team is ready to help.

Fill out the form below, and one of our application engineers will reach out to ensure your equipment stays cool under pressure.